Skip to main content

STICKS study – Short-sTretch Inelastic Compression bandage in Knee Swelling following total knee arthroplasty – a feasibility study

Abstract

Background

Postoperative knee swelling is common and impairs early postoperative function following total knee arthroplasty. It was hypothesised that the use of a short-stretch, inelastic compression bandage would reduce knee swelling and improve pain and early function. The aim of this study was to provide preliminary data and test feasibility with a view to informing a larger, future trial.

Methods

Fifty consecutive patients selected for primary total knee arthroplasty underwent distance randomisation to receive a short-stretch, inelastic compression bandage or a standard wool and crepe bandage for the first 24 h postoperatively. Study feasibility including recruitment rates, retention rates and complications were analysed. The Oxford Knee Score, the EQ-5D-3L index score, knee swelling, knee range of motion, visual analogue pain score and length of stay were compared between groups. Analysis of covariance (ANCOVA) was performed adjusting for the preoperative measurement.

Results

Sixty-eight percent of eligible patients were recruited into the trial. The retention rate was 88%. There were no complications regarding compression bandage use. There was a greater mean but non-significant improvement in Oxford Knee Score (p = 0.580; point estimate = 2.1; 95% CI −3.288 to 7.449) and EQ-5D-3L index score (p = 0.057; point estimate = 0.147; 95% CI −0.328 to 0.005) in the compression bandage group at 6 months. There was no significant difference between groups regarding knee swelling, knee range of motion, visual analogue pain score, complications and length of stay.

Conclusion

Preliminary data suggests that the use of an inelastic, short-stretch compression bandage following total knee arthroplasty is a safe technique that is acceptable to patients. A larger, multicentre trial is required to determine its effect postoperatively.

Trial registration

The study was registered with Current Controlled Trials, identifier: ISRCTN86903140. Registered on 30 May 2013.

Peer Review reports

Background

Total knee arthroplasty is a common and highly successful operation in the management of osteoarthritis. However, postoperative knee swelling is a common problem due to intra-articular bleeding and inflammation of periarticular tissues [1]. This results in decreased functional performance as a result of quadriceps weakness [2] and arthrogenic reflex inhibition due to pain [3] which can delay rehabilitation, increase hospital length of stay and decrease patient-reported outcomes [4, 5]. Additionally, excessive knee swelling is associated with increased rates of wound dehiscence and infection [6].

Intraoperative techniques to reduce intra-articular bleeding, such as surgical technique [7], tourniquets [8] and medication [9] are features in enhanced recovery programmes. However, postoperative methods, including the use of a cold compress [10], cryotherapy [11], elastic bandaging [12] and compression bandages [13, 14] have had limited success.

Compression bandage therapy is the established treatment of venous ulcers and lymphoedema [15, 16]. It is hypothesised that the application of this external compression aids venous return and reduces hydrostatic pressure in the leg by (1) improving the efficacy of the calf-muscle pump and (2) moving blood from the superficial to the deep venous system, subsequently allowing movement of fluid from the interstitial space. The use of inelastic bandages are preferred in arthroplasty as they have a low, tolerable resting pressure but a more effective activation of the deep venous system and calf-muscle pump with ambulation compared to their elastic counterparts [17].

The efficacy in total knee arthroplasty is still unclear due to conflicting results in the medical literature and heterogeneous methodology [13, 1820]. We hypothesised that the use of a compression bandage in total knee replacement would improve postoperative pain, swelling and functional outcomes. The aim of this study was (1) to test study feasibility in the form of eligibility, recruitment rate, attrition rates and bandage complications, (2) to derive preliminary subjective and objective data and (3) to derive a power calculation for the Oxford Knee Score using preliminary data.

Methods

The study was a prospectively enrolled, randomised controlled feasibility study conducted at two hospital sites within Northumbria Healthcare NHS Foundation Trust. Ethical approval was obtained (13/NE/0137) and the study was registered with Current Controlled Trials (ISRCTN86903140). A protocol paper with complete methodology was published previously [21]. A Consolidated Standards of Reporting Trials (CONSORT) flow chart (Fig. 1) was utilised.

Fig. 1
figure 1

Consolidated Standards of Reporting Trials (CONSORT) flow chart

Participant recruitment

Fifty patients selected for total knee arthroplasty were enrolled in the study between November 2013 and June 2014. The inclusion criteria for the study included (1) primary total knee arthroplasty for osteoarthritis, (2) age over 18 years and (3) being able to provide written, informed consent. Exclusion criteria included (1) peripheral vascular disease characterised by an Ankle-Brachial Pressure Index (ABPI) <0.8, (2) peripheral neuropathy and (3) Body Mass Index (BMI) >40.

Patients were randomised on the day of surgery by electronic distance randomisation using the website http://www.sealedenvelope.com. The randomisation process was done in random permuted blocks to allow even balancing of the groups. Patients were allocated to the control group or the compression bandage group. There was no difference in baseline characteristics (Table 1). Preoperative measurements (below) were recorded prior to randomisation to reduce bias.

Table 1 Patient demographics. Standard deviations in parentheses

Control group

Patients underwent primary total knee arthroplasty under the care of one of two consultant orthopaedic surgeons (SM, MR). Surgery was performed under general anaesthesia or spinal anaesthesia and sedation. Intra-venously administered (IV) antibiotics (gentamicin 3 mg/kg and teicoplanin 400 mg IV) and tranexamic acid (30 mg/kg IV up to 2.5 g) were administered and a tourniquet used. A Nexgen cruciate-retaining total knee arthroplasty was used (Zimmer, Swindon, United Kingdom) with Palacos R + G bone cement (Heraeus Medical, Newbury, United Kingdom). Intra-operative periarticular injections of 80 ml 0.125% bupivacaine were infiltrated and a further 20-ml 0.125% bupivacaine bolus given via intra-articular wound catheter after wound closure. The skin was closed using surgical skin clips, which were removed at 10 to 14 days post-operatively. A hydrocolloid dressing (Aquacel Surgical, Convatec Ltd., Flintfield, UK) was used for the wound. Standard bandaging consists of a soft inner layer (Soffban, BSN Medical Ltd., Brierfield, UK) applied from 10 cm below to 10 cm above the patella with a 50% overlap of bandage, followed by a similar outer layer of crepe bandage (BSN Medical Ltd., Brierfield, UK) prior to deflation of the tourniquet.

The bandage and wound catheter were removed at 24 h leaving the hydrocolloid wound dressing in situ. This dressing stayed on until the clips were removed at 10–14 days. A cryocuff was used after 24 h.

Compression bandage group

Patients received a compression bandage over the hydrocolloid surgical wound dressing instead of the routine wool and crepe bandage. Following tourniquet removal a soft inner layer (Soffban, BSN Medical Ltd., Brierfield, UK) was applied from the toes to the groin on the affected leg with a 50% overlap of bandage. Following this the outer compressive layer bandage (Actico bandage, Activa Healthcare Ltd., UK) was applied firmly over the top, again with a 50% overlap of bandage. The bandage was pulled to full stretch before it was wrapped around the leg to ensure adequate compression in the application. It was applied after release of the tourniquet by necessity due to its length up the thigh. To ensure homogeneity in bandage application, the operating surgeons were shown a training video on correct application of the bandage and were given a tutorial on bandage application with real-life bandage application and feedback. The bandage was removed at 24 h post surgery leaving the hydrocolloid wound dressing in situ.

Study feasibility

Recruitment, retention and refusal rates were calculated. The proportion of patients undergoing primary total knee arthroplasty who did not meet the eligibility criteria was also calculated to ensure this was not too restrictive. Ease of application and tolerance of the compression bandage was determined qualitatively by the operating surgeons and patients, respectively. Potential adverse risks associated with the use of the compression bandage, such as pain, wound dehiscence and blistering, were recorded and rates calculated.

Outcome measures

The Oxford Knee Score was measured preoperatively and at 6 months in line with UK Health and Social Care Programme Patient Reported Outcome Measures. The EuroQol EQ-5D-3L questionnaire was measured preoperatively and at 6 months.

Knee swelling and range of motion were measured preoperatively, daily until discharge and at 6 weeks. Visual analogue pain scores were recorded preoperatively, daily until discharge (pre- and post-physiotherapy) and at 6 weeks.

Length of hospital stay, readmission rates and complications were also recorded using hospital episode statistic data.

Statistical analysis

A secure Excel database was used to record data (Microsoft Inc., Albuquerque, NM, USA). Statistical analysis was performed using SPSS version 23.0 (SPSS Inc., Chicago, IL, USA).

For each outcome measure (Oxford Knee Score, EQ-5D-3L index score, knee swelling, range of motion, visual analogue scale score) the two groups were compared at each applicable set time point (preoperative, day 1, day 2, 6 weeks, 6 months) using analysis of covariance (ANCOVA) with the baseline preoperative measurement set as the co-variate. Statistical significance was denoted at p < 0.05.

A power calculation was performed based on the mean and standard deviations of the Oxford Knee Scores collected from this data to inform a future, larger trial. The risk of a type 1 error was set at 0.05 and a type II error at 0.20. The retention rate from feasibility data was incorporated into the final sample size number to allow for possible patient dropout.

Results

Study feasibility

Of the 94 total knee arthroplasties performed during the time period, 20 (21%) did not meet the inclusion criteria. Using the 74 eligible patients, the recruitment rate was 68% (n = 50). Thirty-two percent (n = 24) of patients were seen in clinic but did not receive patient information in a timely manner and were not enrolled. There were no refusals of participation in the study.

During the trial, one patient was excluded from the trial in the control group due to an unplanned complex knee replacement which did not meet the inclusion criteria. Two patients in the control group and four patients in the compression bandage group did not complete 6-month follow-up and could not be analysed (dropout rate 12%) (Fig. 1).

There were no reported problems with bandage application by the operating surgeons and the bandage was well-tolerated by patients, with no reports of discomfort or restriction. There were no reported skin complications with the compression bandages.

Outcomes

  1. 1.

    Oxford Knee Score

    There was a mean Oxford Knee Score improvement of 11.0 in the control group and 13.1 in the compression bandage group. Whilst the point estimate (2.1) was nearing the minimally clinically significant difference of 3.0, the change in score was not statistically significant (p = 0.580; 95% CI −3.288 to 7.449) (Table 2)

    Table 2 Oxford Knee Score and EQ-5D-3L index measurements – standard deviations in parentheses. Point estimate refers to mean difference between groups
  2. 2.

    EQ-5D-3L index

    There was a mean improvement in the EQ-5D-3L index score in the compression bandage group compared to the control group at 6 months, but this was not statistically significant (p = 0.057; point estimate = 0.147; 95% CI −0.328 to 0.005) (Table 2)

  3. 3.

    Knee swelling

    There was an increase in mean knee swelling in both groups on day 1 post-operatively, which increased further at day 2 post-operatively. However, these values were close to pre-operative levels by week 6, with the exception of the knee circumference in both groups. There was, however, no significant statistical difference between groups at any time point (Fig. 2)

    Fig. 2
    figure 2

    Bar chart to show mean circumference (cm) of the leg pre- and post-total knee arthroplasty. Error bars represent interquartile range. No statistical significance was found between groups at any time point

  4. 4.

    Range of motion

    There was a decline in mean range of motion post-operatively in both groups, which decreased further at day 2 post-operatively. However, similarly to knee swelling, these values were close to pre-operative levels by week 6. There was large variation in initial measurements in both groups, reflecting the varying degrees of restriction of the knee due to osteoarthritis and fixed-flexion deformity. There was no significant statistical difference between groups at any time point (Fig. 3)

    Fig. 3
    figure 3

    Bar chart to show mean total range of motion (degrees) of the leg pre- and post-total knee arthroplasty. Error bars represent inter-quartile range. No statistical significance was found between groups at any time point

  5. 5.

    Pain scores

    There was an improvement between pain scores in both groups at 6 weeks compared to pre-operatively. There was a small increase in pain scores in the compression bandage group on day 1 and day 2 but this was not significant. There was no significant statistical difference in pain scores between groups at any time point (Table 3)

    Table 3 Mean visual analogue pain score – standard deviations in parentheses. Point estimate refers to mean difference between groups
  6. 6.

    Length of stay and complications

    The mean length of stay was 3.3 days in the control group and 3.1 days in the compression group (p = 0.749; point estimate = 0.2; 95% CI −0.815 to 1.125). There were no registered infections or thromboembolic events in either group

Discussion

The main finding of this feasibility study was that the study was acceptable to patients with 68% recruitment rate of eligible patients. Attrition was relatively low at 12% and the intervention was acceptable to patients with no documented complications associated with the bandage use.

In terms of clinical outcomes there was a greater mean improvement in the Oxford Knee Score in the compression bandage group. Whilst the 95% confidence interval (−3.288 to 7.449) was wide it did include the three-point difference associated with a clinically important difference. There was a mean greater mean improvement in EQ-5D-3L index scores at 6 months in the compression bandage group, but this was not statistically significant (p = 0.057; point estimate = 0.147; 95% CI −0.328 to 0.005). No statistical difference was found between the groups regarding knee range of motion, knee swelling or pain at any time point.

We accept that there are limitations with the current study. With regards to the study protocol, it was not possible to blind patients or investigators to the intervention, which may introduce bias. Secondly, interobserver variation is a known limitation of objective knee measurements including range of motion and circumference. It is possible that this may account for some of the variation between subjects and consequently, in combination with the large sample size required for the definitive trial, will not be used. Thirdly, there was a large proportion of patients who were eligible for the trial but not enrolled (32%). This was due to the logistics of research nurse availability and not patient demographics or comorbidities. All patients who were approached regarding the trial agreed to participate. Finally, whilst the primary aim was to ascertain feasibility of the study, the study measurements were underpowered and at risk of type II error. Using this preliminary data for Oxford Knee Score, incorporating attrition rate and standard deviation with 90% power, we would need the following number of participants to determine statistical significance: 354; 790; 3088 for a 3-, 2- and 1-point difference, respectively. These figures will form the basis of the future multicentre study.

In a randomised controlled trial of 60 patients undergoing unicondylar knee arthroplasty, Pinsornsak et al. found no difference in swelling, blood loss or pain at 24 h and 48 h postoperatively between a modified Robert-Jones bandage and a standard wool and crepe bandage [19]. Whilst the bandaging technique was different, the findings are similar to our study.

In contrast, Charalambides et al. found that patients had improved range of motion (knee flexion) and decreased length of stay when a compression bandage was used [14]. However, the study of 150 patients was not randomised and relied on retrospective data in the cohort that received the standard wool and crepe bandages. It was also not performed in an enhanced recovery programme setting. A study by Cheung et al. found similar findings regarding improved knee flexion in the compression bandage group, with associated lower incidence of walking aids at discharge [20]. Anderson et al. found that the use of a compression bandage and local anaesthetic infiltration was associated with significant improvement in pain scores at 8 h but not 24 h postoperatively [13]. In our present study, no significant difference in pain scores were seen 24 h postoperatively. The local anaesthetic infiltration in both our groups may have influenced this. There was a small, non-significant increase in pain scores in the compression bandage group during day 1 and day 2 post-operatively, but this did not tally with qualitative information on the bandage provided by the patients.

To our knowledge this is the first study to utilise patient-reported outcome measures with the use of compression bandages after total knee arthroplasty. Whilst not statistically significant, the mean improvement in Oxford Knee Score of 2.1 in the compression bandage group is near the minimal clinically significant difference for the Oxford Knee Score [22]. The greater mean improvement in the EQ-5D-3L index score (p = 0.057; point estimate = 0.147; 95% CI −0.328 to 0.005) in the compression group also follows this trend. However, these results should be interpreted with caution due to the small sample size. As the compression bandage was easy to apply and well-tolerated by patients, without any documented complications, further investigation of its use in a larger, multicentre trial is warranted.

Conclusion

Feasibility data suggests that the compression bandage is easy to use and well-tolerated. No statistically significant differences were seen for post-operative scores between groups. However, there was a marginal trend to an improvement in patient-reported outcome measures at 6 months in the compression bandage group. Future work should be directed at further investigation of these patient-reported outcome measures in a larger, multicentre trial.

References

  1. Holm B, Kristensen MT, Bencke J, Husted H, Kehlet H, Bandholm T. Loss of knee-extension strength is related to knee swelling after total knee arthroplasty. Arch Phys Med Rehabil. 2010;91:1770–6.

    Article  PubMed  Google Scholar 

  2. Mizner RL, Snyder-Mackler L. Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty. J Orthop Res. 2005;23:1083–90.

    Article  PubMed  Google Scholar 

  3. Fahrer H, Rentsch HU, Gerber NJ, Beyeler C, Hess CW, Grunig B. Knee effusion and reflex inhibition of the quadriceps. A bar to effective retraining. J Bone Joint Surg. 1988;70:635–8.

    Article  CAS  Google Scholar 

  4. Moretti B, Notarnicola A, Moretti L, Setti S, De Terlizzi F, Pesce V, et al. I-ONE therapy in patients undergoing total knee arthroplasty: a prospective, randomized and controlled study. BMC Musculoskelet Disord. 2012;13:88.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Williams DP, O’Brien S, Doran E, Price AJ, Beard DJ, Murray DW, et al. Early postoperative predictors of satisfaction following total knee arthroplasty. Knee. 2013;20:442–6.

    Article  CAS  PubMed  Google Scholar 

  6. Yu GV, Schubert EK, Khoury WE. The Jones compression bandage. Review and clinical applications. J Am Podiatr Med Assoc. 2002;92:221–31.

    Article  PubMed  Google Scholar 

  7. Kumar N, Saleh J, Gardiner E, Devadoss VG, Howell FR. Plugging the intramedullary canal of the femur in total knee arthroplasty: reduction in postoperative blood loss. J Arthroplasty. 2000;15:947–9.

    Article  CAS  PubMed  Google Scholar 

  8. Levine BR, Haughom B, Strong B, Hellman M, Frank RM. Blood management strategies for total knee arthroplasty. J Am Acad Orthop Surg. 2014;22:361–71.

    Article  PubMed  Google Scholar 

  9. Martin JG, Cassatt KB, Kincaid-Cinnamon KA, Westendorf DS, Garton AS, Lemke JH. Topical administration of tranexamic acid in primary total hip and total knee arthroplasty. J Arthroplasty. 2014;29(5):889–94.

    Article  PubMed  Google Scholar 

  10. Morsi E. Continuous-flow cold therapy after total knee arthroplasty. J Arthroplasty. 2002;17:718–22.

    Article  PubMed  Google Scholar 

  11. Adie S, Kwan A, Naylor JM, Harris IA, Mittal R. Cryotherapy following total knee replacement. Cochrane Database Syst Rev. 2012;9:CD007911.

    Google Scholar 

  12. Hughes DL, Crosby AC. Treatment of knee sprains: modified Robert Jones or elastic support bandage? J Accid Emerg Med. 1995;12:115–8.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  13. Andersen LO, Husted H, Otte KS, Kristensen BB, Kehlet H. A compression bandage improves local infiltration analgesia in total knee arthroplasty. Acta Orthop. 2008;79:806–11.

    Article  PubMed  Google Scholar 

  14. Charalambides C, Beer M, Melhuish J, Williams RJ, Cobb AG. Bandaging technique after knee replacement. Acta Orthop. 2005;76:89–94.

    Article  PubMed  Google Scholar 

  15. Franks PJ, Moody M, Moffatt CJ, Martin R, Blewett R, Seymour E, et al. Randomized trial of cohesive short-stretch versus four-layer bandaging in the management of venous ulceration. Wound Repair Regen. 2004;12:157–62.

    Article  PubMed  Google Scholar 

  16. Pike C. Using Actico bandaging for chronic oedema/lymphoedema management. Br J Nurs. 2011;20(1246):8–51.

    Google Scholar 

  17. Spence RK, Cahall E. Inelastic versus elastic leg compression in chronic venous insufficiency: a comparison of limb size and venous hemodynamics. J Vasc Surg. 1996;24:783–7.

    Article  CAS  PubMed  Google Scholar 

  18. Munk S, Jensen NJ, Andersen I, Kehlet H, Hansen TB. Effect of compression therapy on knee swelling and pain after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2013;21:388–92.

    Article  PubMed  Google Scholar 

  19. Pinsornsak P, Chumchuen S. Can a modified Robert Jones bandage after knee arthroplasty reduce blood loss? A prospective randomized controlled trial. Clin Orthop Relat Res. 2013;471:1677–81.

    Article  PubMed  PubMed Central  Google Scholar 

  20. Cheung A, Lykostratis H, Holloway I. Compression bandaging improves mobility following total knee replacement in an enhanced recovery setting. J Perioper Pract. 2014;24(4):84–6.

    CAS  PubMed  Google Scholar 

  21. Brock TM, Sprowson AP, Muller S, Reed MR. Short-stretch inelastic compression bandage in knee swelling following total knee arthroplasty study (STICKS): study protocol for a randomised controlled feasibility study. Trials. 2015;16(1):87.

    Article  PubMed  PubMed Central  Google Scholar 

  22. Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, et al. The use of the Oxford Hip and Knee scores. J Bone Joint Surg. 2007;89-B(8):1010–4.

    Article  Google Scholar 

Download references

Acknowledgements

The authors are very grateful to York Trials Unit, UK for the definitive trial power analysis and manuscript advice. The authors would like to thank the participants involved in the study and the research team, Chris Herriot (clinical research nurse), Clare Casson and Diane Williams (senior physiotherapists).

Funding

The study was funded by Northumbria Healthcare NHS Foundation Trust.

Availability of data and materials

Data available on request.

Authors’ contributions

This manuscript outlines independent investigator-initiated research. The views expressed are solely those of the authors. MR conceived the study, designed the study, participated in recruitment and reviewed the manuscript. TB designed the study, participated in recruitment and wrote the manuscript. AS designed the study. SM participated in recruitment and reviewed the manuscript. With the exception of AS, who is now deceased, all authors were involved in drafting the manuscript and revising it for important intellectual content and give permission for this version to be published.

Authors’ information

TB is a specialist registrar in trauma and orthopaedic surgery. SM and MR are consultant orthopaedic surgeons.

Competing interests

The authors declare that they have no competing interests.

Ethical approval and consent to participate

Ethical approval was obtained (13/NE/0137) and the study was registered with Current Controlled Trials (ISRCTN86903140). Informed consent was given by all participants.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to T. M. Brock.

Additional information

A. P. Sprowson is deceased.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Brock, T.M., Sprowson, A.P., Muller, S. et al. STICKS study – Short-sTretch Inelastic Compression bandage in Knee Swelling following total knee arthroplasty – a feasibility study. Trials 18, 6 (2017). https://doi.org/10.1186/s13063-016-1767-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13063-016-1767-5

Keywords